IBM Server Site

IBS Home Up

5494 Recovery

Recovery Attempt 1

Check for an active "RD" (Ready) light on the controller
Cycle power to remote controller
(cycle power only at the remote site not at the local / host site)
  • wait and see if the stations come up at this point
  • you may have to vary off then on the stations at the remote location
All workstations and printers should be working now
If the stations still won't respond continue to recovery attempt 2

Recovery Attempt 2

Vary off workstations
Vary off controller
Cycle power to the remote controller
Wait for the solid green "RD" light to come appear
  • The following lights should be solid green
    TD RD ACT LNK
    x x x x
Vary on controller
Vary on workstations & printers
All workstations and printers should be working now

[back to top]

IBS Lumber and Building Material Software Copyright © 2006 IBS Lumber Software Inc (TM)
Last modified: November 7, 2011

IBS Sales & Support 888-640-1252
Main Office 888-640-1252
Fax IBS 877-712-8937

All pages contained in this support website are not intended for general public distribution. Any material here can be considered private, confidential with various copyrights and restrictions against public release. You 'the browser' cannot legally release this information for general public distribution.