SRC Reference B900C7FF

SI16941 - IPL-SRCB90037FF QSYCHGSP fails during IPL

PTF ( Program Temporary Fixes ) Cover letter

Abstract

IPL-SRCB90037FF QSYCHGSP fails during IPL

Pre/Co-Requisite PTF / Fix List


REQ LICENSED PTF/FIX LEVEL
TYPE PROGRAM REL NUMBER MIN/MAX OPTION
---- -------- --- ------- ------- ------
CO 5722SS1 530 SI16940 00/00 0000



NOTICE:
-------
Application of this PTF may disable or render ineffective programs that
use system memory addresses not generated by the IBM translator,
including programs that circumvent control technology designed to limit
interactive capacity to purchased levels. This PTF may be a prerequisite
for future PTFs. By applying this PTF you authorize and agree to the
foregoing.

This PTF is subject to the terms of the license agreement which
accompanied, or was contained in, the Program for which you are obtaining
the PTF. You are not authorized to install or use the PTF except as part
of a Program for which you have a valid Proof of Entitlement.

SUBJECT TO ANY WARRANTIES WHICH CAN NOT BE EXCLUDED OR EXCEPT AS EXPLICITLY
AGREED TO IN THE APPLICABLE LICENSE AGREEMENT OR AN APPLICABLE SUPPORT
AGREEMENT, IBM MAKES NO WARRANTIES OR CONDITIONS EITHER EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON INFRINGEMENT,
REGARDING THE PTF.

The applicable license agreement may have been provided to you in printed
form and/or may be viewed using the Work with Software Agreements (WRKSFWAGR)
CL command.


[back to top]

APAR Error Description / Circumvention

DESCRIPTION OF PROBLEM FIXED FOR APAR SE18773 :
-----------------------------------------------
Using the DST option to reset the QSECOFR password causes a
failure during IPL. The reference code data contains:
B90037FF
0DB00080
20200010
D8E2E8C3
C8C7E2D7
40400340
C3D7C6F2
F5F2F400
Indicating message CPF2524 occurred in QSYCHGSP.

CORRECTION FOR APAR SE18773 :
-----------------------------
The IPL program calling QSYCHGSP will be changed
to correct the problem.

CIRCUMVENTION FOR APAR SE18773 :
--------------------------------
None.

Activation Instructions


None.

Special Instructions


If this PTF is applied as a delayed PTF, the DST option to reset the Ope
rating system QSECOFR password should not be used until after the IPL to
apply this PTF.

********************************************************************
THE FOLLOWING ARE SUPERSEDED SPECIAL INSTRUCTIONS. IF THE SUPERSEDED
PTF HAS ALREADY BEEN APPLIED AND ITS SPECIAL INSTRUCTION FOLLOWED,
IT IS NOT NECESSARY TO FOLLOW THAT SPECIAL INSTRUCTION AGAIN.
********************************************************************

SPECIAL INSTRUCTIONS FOR SUPERSEDED PTF SI14089 :
=================================================

The system should be IPLed after this PTF is applied to fix the problem.

Default Instructions

THIS PTF CAN BE APPLIED IMMEDIATE OR DELAYED.

Supersedes

PTF/FIX NO(S). APAR TITLE LINE
-------------- ------------------------------------------------------------
SI14349 OSP-SRCC9002C10 hang during IPL
SI14089 OSP-INCORROUT START PROBLEM LOGGING UNTIL QSYSWRK STARTS

Summary Information

System.............................................. iSeries
Models..............................................
Release............................................ V5R3M0
Recompile........................................ N
Library................................................ QSYS
MRI Feature...................................... NONE
Cum Level...................................... C5032530

System i Support

[back to top]

IBS Lumber and Building Material Software Copyright © 2006 IBS Lumber Software Inc (TM)
Last modified: November 7, 2011

IBS Sales & Support 888-640-1252
Main Office 888-640-1252
Fax IBS 877-712-8937

All pages contained in this support website are not intended for general public distribution. Any material here can be considered private, confidential with various copyrights and restrictions against public release. You 'the browser' cannot legally release this information for general public distribution.

remote support: http://www.gotomeeting.com | remote support download program